🔧 BOGE SERVICE 24H - Do you have a compressor problem?+48 606 282 624

    Compressor service BOGE

    Modern Tech Group provides professional service for BOGE screw compressors. BOGE compressors are among the most reliable devices on the compressed air market, but even the highest quality requires regular maintenance and professional service.

    A reliable compressed air installation is the foundation for the operation of production plants, assembly lines, paint shops, and pneumatic processes. Any unplanned interruption in compressed air supply generates production losses, which is why it is essential to keep compressors in optimal technical condition.

    Our team of engineers has many years of experience in servicing BOGE compressors of all series - from compact workshop units to installations with capacities exceeding 30 m³/min.

    BOGE compressor service for industry

    BOGE compressors are used in almost every industry - automotive, food, pharmaceutical, chemical, electronic, and metallurgical. Regular inspections with timely replacement of air filters, oil, and separators protect the screw block from costly regeneration.

    Professional BOGE service includes replacement of consumables, verification of operating parameters, control of the focus control system, checking the tightness of the installation, and optimization of settings based on current compressed air demand.

    Most common BOGE compressor failures

    From our service practice - symptoms most frequently reported by customers. Do you recognize any of them? We will quickly diagnose the cause and implement an effective solution.

    Lack of working pressure
    Compressor goes into idle run
    System overheating
    Oil leaks
    Decrease in compressor efficiency
    Controller alarms and errors

    Lack of pressure most often results from a damaged inlet valve, solenoid valve failure, or installation leaks. Idle run - the compressor runs but does not build pressure - may be caused by a minimum pressure valve malfunction or controller error. Overheating indicates a clogged oil cooler, low oil level, or fan failure. Oil leaks mean worn seals. BOGE focus control alarms signal both minor sensor malfunctions and serious mechanical failures.

    BOGE compressor models we service

    We service a full range of screw compressors - from small compact units to large industrial installations.

    BOGE S series - oil-injected screw (S 21 - S 341, ~11-250 kW)
    BOGE C series - compact screw (C 4 - C 30, 3-22 kW)
    BOGE SF series - compact variable-speed
    BOGE SLF series - variable-speed screw (up to 355 kW)
    BOGE SO series - oil-free screw (up to 355 kW)
    BOGE bluekat - oil-free Class 0 (30-45 kW)
    BOGE K series - piston (0.75-18.5 kW)
    BOGE HST series - oil-free high-speed turbo

    Don't see your model? We also service older and discontinued BOGE compressor series - contact us.

    Scope of BOGE service offerings

    From routine inspection to screw element overhaul - comprehensive service for your compressed air system.

    BOGE compressor diagnostics

    Precise fault diagnostics using modern measuring equipment and reading controller error codes.

    Periodic inspections

    Regular inspections according to BOGE manufacturer's schedule - key to trouble-free compressor operation.

    Air filter replacement

    Installation of inlet filters ensuring optimal quality of sucked air and protection of the screw block.

    Oil filter replacement

    Replacement of oil filters guaranteeing proper lubrication and cooling of the compression elements.

    Oil separator replacement

    Installation of oil separators eliminating residual oil content in compressed air.

    Screw module repair

    Regeneration and replacement of screw blocks - we restore full efficiency of the BOGE compressor.

    Controller repair

    Service of BOGE focus control controllers, pressure sensors, temperature sensors, and automation components.

    Installation modernization

    Optimization of existing compressed air systems in terms of efficiency and energy savings.

    BOGE service throughout Poland

    We perform mobile service - technician travel to the plant, diagnostics, and on-site repair. Main service regions:

    BOGE compressor breakdown?

    Call us - emergency service 24/7. Fast diagnostics, proven parts, replacement compressor 4-75 kW for the duration of the repair.

    Why Modern Tech Group?

    Many years of experience in compressor service
    Quick response time - service available 24/7
    B2B service - service agreements for industrial plants
    Proven components and consumables
    Transparent cost estimates and competitive prices
    Warranty for performed repairs and installed parts
    Experienced engineers and technicians
    Comprehensive service - from diagnostics to modernization

    How service works step-by-step

    Clear service process - from reporting to handover of a fully functional compressor.

    01

    Diagnostics

    Technician arrival, external inspection, controller log and error code reading.

    02

    Parameter analysis

    Measurement of pressure, temperature, efficiency, and analysis of consumable wear.

    03

    Fault identification

    Precise determination of the cause of failure based on collected diagnostic data.

    04

    Repair / replacement

    Repair or replacement of damaged components using proven parts.

    05

    Operation test

    Compressor startup, verification of operating parameters, and submission of service report.

    Frequently asked questions

    The cost of service depends on the compressor model, scope of work, and technical condition of the device. A periodic inspection with consumable replacement costs from several hundred to several thousand PLN. Contact us for an individual quote - tel. +48 606 282 624.

    BOGE manufacturer recommends inspections every 2000-4000 operating hours or at least once a year. The frequency depends on the intensity of use, environmental conditions, and compressor type. Regular inspections prevent costly failures and extend the device's lifespan.

    Idle run means the compressor is working but not building pressure. The most common causes are: damaged inlet valve, solenoid valve failure, incorrect controller settings, or leaks in the installation.

    Contact

    Need an inspection, overhaul or rental? Fill out the form - we'll respond within 24 hours.

    Send inquiry

    0/2000

    Find us on the map

    ul. Słowackiego 201, 26-600 Radom